Skip to main content
Advanced Search
Search Terms
Content Type

Exact Matches
Tag Searches
Date Options
Updated after
Updated before
Created after
Created before

Search Results

351 total results found

2.3.2 Initial pitch inside the total oval — Edge vs. Center & Pitch Included Yes/No

02 Settings 2.3 — Thumb Hole Preferences

2.3.2   oval When drilling an oval hole, Spectre Cloud needs a reference point from which to calculate the initial pitch of that hole. Because an oval opening has width — unlike a round hole, which has a single center point — there are two valid ways to defin...

chapter
2.3 — Thumb Hole Preferences
type
oval
section
Settings

2.3.3 Oval Width Calculator — Bit Size, Decimal, or Difference input method

02 Settings 2.3 — Thumb Hole Preferences

2.3.3   oval When calculating an oval thumb hole, Spectre Cloud needs to know the oval width — the final size of the opening the bowler's thumb will sit in. This setting controls how you input that measurement. There are three options: Oval Width (Bit Size), ...

section
Settings
chapter
2.3 — Thumb Hole Preferences
type
oval

2.3.5 Oval Cut 'Move' Direction — V/H, H only, V only, or None

02 Settings 2.3 — Thumb Hole Preferences

2.3.5   oval The Oval Cut Move Direction setting controls which directional components Spectre Cloud calculates and displays when outputting oval cut values. Depending on your drill press type and how you cut ovals, you may work with both vertical and horizon...

section
Settings
chapter
2.3 — Thumb Hole Preferences
type
oval

2.3.6 Flip V/H on oval cuts — matching your drill press DRO display order

02 Settings 2.3 — Thumb Hole Preferences

2.3.6   oval The Flip V/H on oval cuts setting controls the display order of the vertical and horizontal values in the oval cut cards shown by the Spectre Cloud oval calculator. This setting should match the order your drill press digital readout (DRO) displa...

section
Settings
chapter
2.3 — Thumb Hole Preferences
type
oval

2.4.1 Does your machine display Right Pitch Positive? (YES / NO)

02 Settings 2.4 — Drill Press Calibration

Does your machine display Right Pitch Positive? (YES / NO) 2.4.1   calibration   Different drill presses use different sign conventions when displaying pitch values — some treat right pitch as positive, others treat it as negative. This setting tells Spectr...

section
Settings
chapter
2.4 — Drill Press Calibration
type
calibration

2.4.2 Does your machine display Forward Thumb Pitch Positive? (YES / NO)

02 Settings 2.4 — Drill Press Calibration

Does your machine display Forward Thumb Pitch Positive? (YES / NO) 2.4.2   calibration   Just as drill presses vary in how they represent lateral (right/left) pitch direction, they also differ in how they display forward and reverse thumb pitch. This settin...

chapter
2.4 — Drill Press Calibration
section
Settings
type
calibration

2.4.3 Display +/- in pitch tiles — showing direction arrows to avoid errors

02 Settings 2.4 — Drill Press Calibration

Display +/- in pitch tiles — showing direction arrows to avoid errors 2.4.3   calibration   Even with sign conventions correctly configured in 2.4.1 and 2.4.2, a raw + or - symbol on a pitch tile can be easy to miss at a glance — especially under shop light...

section
Settings
chapter
2.4 — Drill Press Calibration
type
calibration

2.4.4 Matching Spectre output to your specific drill press brand/model

02 Settings 2.4 — Drill Press Calibration

Matching Spectre output to your specific drill press brand/model 2.4.4   TIP   calibration Spectre Cloud includes a drill press brand and model selector that automatically configures the pitch sign convention and axis orientation settings to match your mac...

section
Settings
chapter
2.4 — Drill Press Calibration
type
calibration
flag
TIP

2.5.1 Default Layout Type — VLS, 2LS, PAL (Mo Pinel), or NONE

02 Settings 2.5 — Layout Preferences

Default Layout Type — VLS, 2LS, PAL (Mo Pinel), or NONE 2.5.1   layout   The Default Layout Type setting controls which layout system Spectre Cloud pre-selects when a new spec sheet is created. Rather than choosing a layout method from scratch every time, y...

section
Settings
chapter
2.5 — Layout Preferences
type
layout

2.5.1.1 VLS — Storm system for bowlers using thumb

02 Settings 2.5 — Layout Preferences

VLS — Storm system for bowlers using thumb 2.5.1a   layout   The VLS (Versatile Layout System) is a ball layout method developed by Storm Bowling that determines pin and mass bias placement using a bowler's track, PAP (Positive Axis Point), and a small set ...

section
Settings
chapter
2.5 — Layout Preferences
type
layout

2.5.1.2 2LS — Storm system for two-handed bowlers

02 Settings 2.5 — Layout Preferences

2LS — Storm system for two-handed bowlers 2.5.1b   layout   The 2LS (Two-Layout System) is a ball layout method developed by Storm Bowling specifically to address the unique PAP location and track profile of two-handed bowlers. Where VLS was designed with t...

chapter
2.5 — Layout Preferences
type
layout
section
Settings

2.5.1.3 PAL / Dual Angle system

02 Settings 2.5 — Layout Preferences

PAL / Dual Angle system 2.5.1c   layout   The PAL (Performance Axis Layout) system — referred to in Spectre Cloud as Dual Angle — is a ball layout method that uses three measured values to precisely define pin and mass bias placement relative to a bowler's ...

section
Settings
chapter
2.5 — Layout Preferences
type
layout

2.5.1.4 NONE — Manual layout entry

02 Settings 2.5 — Layout Preferences

NONE — Manual layout entry 2.5.1d   layout   When the None layout type is selected in Spectre Cloud, no layout system is applied to the spec sheet. Instead of being guided through a structured set of layout inputs, the driller enters layout information free...

section
Settings
chapter
2.5 — Layout Preferences
type
layout

2.5.2 Default Dual Angle Degree Increments — 1° vs. 5°

02 Settings 2.5 — Layout Preferences

Default Dual Angle Degree Increments — 1° vs. 5° 2.5.2   layout   When entering drilling angle and VAL angle values in a Dual Angle (PAL) layout, Spectre Cloud lets you choose the degree increment used when adjusting angle inputs — either 1° for fine-graine...

section
Settings
chapter
2.5 — Layout Preferences
type
layout

2.6.1 Overview — why leaving all Auto-Suggestions ON saves time

02 Settings 2.6 — Auto-Suggestions

Overview — why leaving all Auto-Suggestions ON saves time 2.6.1   TIP   auto   Spectre Cloud includes a suite of auto-suggestion features that automatically populate recommended values across spec sheets as you work — finger and thumb sizes, pitches, spans,...

section
Settings
chapter
2.6 — Auto-Suggestions
type
auto
flag
TIP

2.6.2 Pitch Suggestion — auto forward pitch based on hand flexibility

02 Settings 2.6 — Auto-Suggestions

Pitch Suggestion — auto forward pitch based on hand flexibility 2.6.2   auto   The Pitch Suggestion setting controls whether Spectre Cloud automatically recommends a forward thumb pitch value based on the bowler's recorded hand flexibility. When enabled, th...

section
Settings
chapter
2.6 — Auto-Suggestions
type
auto

2.6.3 Auto-CLT — lateral pitch of fingers based on CLT chart

02 Settings 2.6 — Auto-Suggestions

Auto-CLT — lateral pitch of fingers based on CLT chart 2.6.3   auto   The Auto-CLT setting controls whether Spectre Cloud automatically suggests a lateral pitch value for the finger holes based on the bowler's Center Line Transformation (CLT) measurement. W...

section
Settings
chapter
2.6 — Auto-Suggestions
type
auto

2.6.4 Auto-Invert standard lateral pitches when changing from RH to LH

02 Settings 2.6 — Auto-Suggestions

Auto-Invert standard lateral pitches when changing from RH to LH 2.6.4   auto   The Auto-Invert setting controls whether Spectre Cloud automatically mirrors lateral pitch values when a spec sheet is switched between a right-handed (RH) and left-handed (LH) ...

section
Settings
chapter
2.6 — Auto-Suggestions
type
auto

2.6.5 Autofill Bridge — auto standard bridge (1/4" Fingertip, 3/8" conventional)

02 Settings 2.6 — Auto-Suggestions

Autofill Bridge — auto standard bridge (1/4" Fingertip, 3/8" conventional) 2.6.5   auto   The Autofill Bridge setting controls whether Spectre Cloud automatically populates the bridge measurement field on a new spec sheet based on the bowler's grip style. W...

section
Settings
chapter
2.6 — Auto-Suggestions
type
auto

2.6.6 Autofill Insert OD — auto drill bit size per insert type and grip

02 Settings 2.6 — Auto-Suggestions

Autofill Insert OD — auto drill bit size per insert type and grip 2.6.6   auto   The Autofill Insert OD setting controls whether Spectre Cloud automatically suggests the correct drill bit size for a bowler's finger holes based on their insert type and grip ...

section
Settings
chapter
2.6 — Auto-Suggestions
type
auto