# 2.6.3 Auto-CLT — lateral pitch of fingers based on CLT chart

# Auto-CLT — lateral pitch of fingers based on CLT chart

<span style="font-family: monospace; color: #6b7280;">2.6.3</span> <span style="border: 1px solid #d1d5db; color: #4b5563; padding: 2px 8px; border-radius: 3px; font-size: 0.85em;">auto</span>

The **Auto-CLT** setting controls whether Spectre Cloud automatically suggests a **lateral pitch value for the finger holes** based on the bowler's **Center Line Transformation (CLT)** measurement. When enabled, the auto-suggestion engine consults the CLT chart and pre-populates the lateral finger pitch field on new spec sheets, removing the need for the fitter to look up and enter the value manually.

## 📐 What Is Center Line Transformation (CLT)?

Center Line Transformation is a measurement taken during the fitting process that captures how the bowler's finger centerline relates to the grip center of the ball. This relationship directly influences how much lateral pitch — if any — the finger holes require to achieve a comfortable, neutral fit that does not place undue stress on the fingers during the swing or release.

- ✅ CLT quantifies the natural lateral offset of the bowler's fingers relative to the ball's grip center.
- ✅ The resulting lateral pitch recommendation compensates for this offset, aligning the finger holes with the bowler's natural grip orientation.
- ✅ Getting lateral finger pitch right reduces grip fatigue, finger stress, and inconsistent ball exit — particularly over a long bowling session or tournament.
- ❌ CLT-based suggestions are a starting point — individual factors such as finger shape, knuckle prominence, and personal comfort should always be assessed physically before drilling.

**Note:** ⚠️ *Verify with your Spectre team: confirm exactly how CLT is measured and recorded in Spectre Cloud — whether it is a numeric value, a derived figure from other measurements, or a category selection — and confirm which CLT chart version the suggestion engine references.*

## 📊 How the CLT Chart Translates to Lateral Pitch

The CLT chart maps a bowler's CLT measurement to a recommended lateral pitch value for the finger holes. Spectre Cloud's Auto-CLT engine performs this lookup automatically when a new spec sheet is opened for a bowler with a CLT measurement on record.

<table id="bkmrk-clt-value-suggested-"><thead><tr><th>CLT Value</th><th>Suggested Lateral Pitch Direction</th><th>Rationale</th></tr></thead><tbody><tr><td>Significant offset toward ring finger</td><td>Lateral pitch toward ring finger</td><td>Compensates for finger centerline displaced toward the ring side</td></tr><tr><td>Minimal offset</td><td>Zero lateral pitch</td><td>Finger centerline aligns naturally with grip center — no compensation needed</td></tr><tr><td>Significant offset away from ring finger</td><td>Lateral pitch away from ring finger</td><td>Compensates for finger centerline displaced toward the middle finger side</td></tr></tbody></table>

**Note:** The table above illustrates the directional logic of CLT-based lateral pitch suggestions. Specific numeric thresholds and output values must be confirmed with the Spectre team before publishing. ⚠️ *Verify with your Spectre team: confirm the actual CLT measurement ranges and corresponding lateral pitch values used by the suggestion engine, and update this table with precise figures.*

## 🛠️ Enabling or Disabling Auto-CLT

1. Navigate to **Settings** from the top menu.
2. Locate the relevant settings section. ⚠️ *Verify with your Spectre team: confirm the exact section name for 2.6.x settings, consistent with earlier pages in this chapter.*
3. Find the **Auto-CLT** option.
4. Toggle the setting on or off according to your shop's preference. ⚠️ *Verify with your Spectre team: confirm whether this is a toggle, checkbox, or other control.*
5. The change takes effect immediately for all new spec sheets. Existing spec sheets are not affected. ⚠️ *Verify with your Spectre team: confirm auto-save behavior, consistent with other settings in this chapter.*

## 🔗 Relationship to Other Pitch Settings and Auto-Suggestions

Auto-CLT operates alongside the other pitch-related settings in chapters 2.4 and 2.6. The lateral pitch value it suggests is displayed using the same sign convention and directional indicator format active for your account — so the suggestion appears in the format your press expects.

- ✅ The suggested lateral pitch respects the **right pitch as positive** sign convention set in **2.4.1**.
- ✅ If directional indicators are enabled (**2.4.3**), the Auto-CLT suggestion will display with the appropriate direction arrow or label.
- ✅ Auto-CLT applies to **finger lateral pitch specifically** — it does not affect thumb lateral pitch, which is governed by separate fitting measurements. ⚠️ *Verify with your Spectre team: confirm whether Auto-CLT applies to both fingers independently, or to the finger pair as a single value.*
- ✅ Overriding the Auto-CLT suggestion is treated the same as any other manual pitch entry — the override is saved to the bowler's history and informs future suggestions.

## ⚙️ When to Consider Turning Auto-CLT Off

- ✅ **Training new staff** — disabling Auto-CLT requires trainees to consult the CLT chart manually and derive lateral pitch independently, building genuine fitting knowledge.
- ✅ **Bowlers with incomplete CLT records** — if a bowler's CLT has not been measured or recorded in Spectre Cloud, the suggestion cannot fire. In these cases, Auto-CLT being on has no effect, but turning it off clarifies that manual entry is always expected for this bowler.
- ✅ **Shops that do not use CLT-based fitting** — if your shop derives lateral finger pitch from a different methodology entirely, Auto-CLT suggestions will conflict with your approach on every spec sheet.
- ❌ Turning Auto-CLT off in a CLT-based shop increases the risk of a fitter skipping lateral pitch entirely or applying a default value without reference to the bowler's actual measurement.

## 📌 What Happens When No CLT Is on Record

If a bowler does not have a CLT measurement recorded in Spectre Cloud, the Auto-CLT engine has no data to work from and will not populate the lateral pitch field. The field will remain blank pending manual entry.

- ✅ No suggestion is preferable to a wrong suggestion — Spectre Cloud will not guess a lateral pitch value without a CLT measurement to base it on.
- ✅ To enable Auto-CLT suggestions for a bowler, ensure their CLT measurement is recorded in their profile before opening a new spec sheet. ⚠️ *Verify with your Spectre team: confirm where CLT is recorded in Spectre Cloud — on the bowler profile, on individual spec sheets, or both.*

## ☁️ Scope of This Setting

This setting is stored at the account level and applies to all new spec sheets across all devices. ⚠️ *Verify with your Spectre team: confirm per-user vs. per-account/shop scope — this chapter is the right place to resolve this question definitively and apply the answer retroactively across all affected pages from 2.3.5 onward.*

### Related Sections

- 2.6.2 — Pitch suggestion: auto forward pitch based on hand flexibility
- 2.6.1 — Overview: why leaving all auto-suggestions on saves time
- 2.6.4 — Next auto-suggestion setting *(if applicable)*
- 2.4.1 — Does your machine display right pitch as positive? Y/N
- 2.4.3 — Display +/- in pitch tiles: showing direction arrows to avoid errors
- 3.x — Bowlers: recording CLT in a bowler profile
- 4.x — Spec Sheet: entering and reviewing lateral finger pitch

**Tip:** CLT is one of those measurements that pays dividends over time — a bowler fitted with accurate lateral finger pitch early in their history will have better Auto-CLT suggestions on every ball that follows. Make recording CLT a routine part of every new bowler intake, not just an occasional step, and the suggestion engine will do progressively more of the work for you.

```